Category

Controller errors

ERROR nn

Error

Remedy

LCD status message

Trouble or status

Remedy

– Check the optional RAM board

for proper connection.

– Check the mounting position of

short plugs and additional RAM
chips (see 7.4).

– Replace the option RAM board.

60

An error was detected by
optional RAM check.

– Check the fan motor for proper

connection and for any presence
of foreign matter in the fan (see
6.5.2-

5

).

– Replace the fan or the Main

Control PCB.

70

A fault occurred in the Fan
motor.

See 6.5.2-

4

.

71

A fault occurred in the fuser
(timeout error etc.).

See 6.5.2-

4

.

72

A fault occurred in the fuser
(thermistor open error).

See 6.5.2-

4

.

73

A fault occurred in the fuser
(thermistor short error).

Replace the power supply board
or the Main Control PCB.

74

Power supply board SSIO
I/F error

– Check the operator panel for

proper connection.

– Replace the flexible cable,

operator panel or Main Control
PCB.

80

I/F timeout occurred between
the Main Control PCB and
the operator panel.

Code

(nn)

Table 6-2 (Cont'd)