3.3.12 Transfer Roller

(1) With the power switch turned off, unplug the AC power cord from the outlet.

(2) Open the stacker cover.

(3) Release TR gear

1

by unlocking the latch

4

of the main unit (never apply an excessive force

when unlocking the latch).

(4) Lift the right side of the transfer roller

2

, and shift it to the right side, then pull it out from the

main unit (at this time, the bearings

3

of the left and right sides of the transfer roller

2

will

release themselves).

3

3

2

1