1pps output, 1pps pulse definition, Tr imble r7 operation – Trimble Outdoors R7 User Manual

Page 114

Advertising
background image

1 1 Event Marker Input and 1PPS Output

1 0 2 Trimble R7/R8 GPS Receiver User Guide

Tr

imble R7 Operation

11.1

1PPS Output

The Trimble R7 receiver can output a one pulse per second (1PPS)
time strobe with an associated ASCII time tag output. The pulse is
output through Port 2 of the receiver using the event marker/1PPS
cable.

111.1

1PPS pulse definition

The leading edge of the pulse coincides with the beginning of each
UTC second, as shown in Figure 11.1. The pulse is driven by an
RS-422 driver between nominal levels of 0 V and 4 V. The leading
edge is positive, rising from 0 V to 4 V.

Figure 11.1

Time tag relation to 1PPS wave form

0 V

4 V

Seconds

Time tag output here

Time tag applies here