Default settings, Tr imble r7 operation – Trimble Outdoors R7 User Manual

Page 97

Advertising
background image

Trimble R7/R8 GPS Receiver User Guide 8 5

Default Settings 9

Tr

imble R7 Operation

9.2

Default Settings

Table 9.1 shows the default settings for the Trimble R7 receiver, as
defined in the default application file.

Table 9.1

Default settings

Function

Factory Default

SV Enable

All SVs enabled

General Controls:

Elevation mask

13°

PDOP mask

7

RTK positioning mode

Low Latency

Motion

Kinematic

Power Output 3

Disabled

1PPS time tags

Off

ASCII time tags

Off

Serial Port 1:

Baud rate

38400

Format

8-None-1

Flow control

None

Serial Port 2:

Baud rate

38400

Format

8-None-1

Serial Port 3:

Baud rate

38400

Format

8-None-1

Flow control

None

Input Setup:

Station

Any

NMEA/ASCII (all messages)

All Ports Off

Streamed output

All Types Off

Offset = 00

RT17/Binary

All Ports Off

CMR output

[Static] CMR: cref ID 0000

RTCM output

RTCM: Type 1 ID 0000

Advertising
This manual is related to the following products:

R8