3.3.2 Temperature and Humidity

The ambient operating environment for the tape drive may not exceed the limits shown in

Table 3-18

.

(The specifications shown in the table are valid for both the internal and tabletop tape drives.)

3.3.3 Storage and Shipment

The ambient storage and shipment environment for the tape drive may not exceed the limits shown in

Table 3-19

. (The specifications shown in the table are valid for both the internal and tabletop tape

drives.)

Table 3-18.

Temperature and Humidity Specification

Specification

Operating Limits

Non-Operating Limits
(Power On, No Tape Loaded)

Wet Bulb Temperature

25 °C (77 °F)

25 °C (77 °F)

Dry Bulb Temperature
Range

10

°

C to 40

°

C (50

°

F to 104

°

F)

10

°

C to 40

°

C (50

°

F to 104

°

F)

Temperature Gradient

11

°

C (20 °F)/hour (across range)

15

°

C (27 °F)/hour (across range)

Relative Humidity

20% to 80% (non-condensing)

10% to 90% (non-condensing)

Humidity Gradient

10%/hour

10%/hour

Table 3-19.

Tape Drive Storage and Shipment Specifications

Specification*

Storage
(Unpacked or Packed)

Shipping

Wet Bulb Temperature

46 °C (114 °F)

46 °C (114 °F)

Dry Bulb Temperature

–40

°

C to 66 °C (–40 °F to 150 °F)

–40 °C to 66 °C (–40 °F to 150 °F)

Temperature Gradient

20 °C (36 °F)/hour (across range)

20 °C (36 °F)/hour (across range)

Relative Humidity

10 to 95% (non-condensing)

10 to 95% (non-condensing)

Humidity Gradient

10%/hour

10%/hour

* Note that these specifications apply to the tape drive only. Media specifications are listed in