2 performing a trial back-up, 3 updating the firmware, Performing a trial back-up -3 – Tandberg Data SDLT 600 User Manual

Page 77: Updating the firmware -3, Performing a trial back-up, Updating the firmware

Advertising
background image

SDLT 600 Product Manual

Chapter 5: Using Your Tape Drive

81-81184-02 REV A01

March 2004

5-3

5.2

Performing a Trial Back-up

Complete the following steps to perform a trial backup and verify correct tape drive installation:

Insert a data cartridge. Push the data cartridge completely into the system. The tape will load
automatically.

Choose a sample file set from the host computer.

Create a backup file and then restore the file set. If the backup file completely restores, without any
errors, you installed the system correctly.

If you experience errors, doublecheck the tape drive’s configuration and setup, using the ideas
provided in

“Troubleshooting” on page 5-12

.

After you have exhausted all troubleshooting alternatives, contact your service representative.

Press the Eject button to unload the data cartridge. If you are unsure which button is the Eject
button, refer to

Figure 5-2 on page 5-9

.

N

OTE

: You can review specific instructions for loading a data cartridge in

Appendix A

,

“Super DLTtape I and Super DLTtape II Data Cartridges”

and

Appendix B

,

“DLTtape VS1 Data Cartridge”

5.3

Updating the Firmware

When you need to update the firmware in a tape drive, you can do it either of two ways:

By directly using the SCSI bus

By creating a firmware image data cartridge (CUP/FUP) to use in either a manual firmware update
or in a library setting.

DLTSage provides the tool that allows you to update the tape drive’s firmware using the SCSI bus, or
to create a CUP/FUP data cartridge for an SDLT 600 tape drive. DLTSage is available on Quantum’s
web site, http://www.quantum.com.

Section 2.5, “Quantum Diagnostics Tools,”

in

Chapter 2

provides

details on locating DLTSage in Quantum’s web site.

The following subsections briefly describe both methods of updating the tape drive firmware.