2 configuring the internal tape drive for termpwr, 3 installing the internal tape drive, Configuring the internal tape drive for termpwr -9 – Tandberg Data SDLT 600 User Manual

Page 57: Installing the internal tape drive -9

Advertising
background image

SDLT 600 Product Manual

Chapter 4: Installing Your Tape Drive

81-81184-02 REV A01

March 2004

4-9

4.4.2 Configuring the Internal Tape Drive for TERMPWR

You must terminate a SCSI bus at each end of the bus. Terminate all signals not defined as
RESERVED, GROUND, or TERMPWR exactly once at each end of the bus. At least one device must
supply terminator power (TERMPWR).

To enable TERMPWR, install the jumper across Pins 1 and 2 (see

Figure 4-3

) on the TERMPWR

jumper block. Remove the jumper to disable TERMPWR. Pins 3 and 4 on this block are reserved and
require no jumper.

Figure 4-3.

TERMPWR Jumper Block on Rear of Tape Drive

4.4.3 Installing the Internal Tape Drive

“Securing the Internal Tape Drive” on page 4-10

describes installing the tape drive by securing the

tape drive in its bay or chassis and connecting the SCSI bus (or Fibre Channel) and power cables.
When you have finished mounting and installing the tape drive, proceed directly to

“Confirming the

Installation” on page 4-25

to confirm the installation.

TERMPWR Block

Pin 1

(Install jumper on Pins 1-2

to enable TERMPWR)

Pin 2

(4 pin)