MIX 56 User Manual

5 Owner Maintenance

122188-10 A0

Telect, Inc.

5-11

2.

In the Filename field, type the base name of the update file (without
extension) and press Enter.

The system will update from two files, “baseName.EXT” and
“baseName.INT.

3.

Tab to the TFTP Host Address field, type the address of the TFTP
server the file resides on, and then press Enter. The address is divid-
ed into four sets of numbers from 0 to 255 each. Type in the four
sets of numbers, separated by a period, then press Enter.

4.

Tab to the [TFTP Load] button and press Enter.

A prompt appears asking you to confirm updating the software.

NOTE

If you get an error message saying TFTP update requires two
cards, it means your system does not have a standby card—you
need to use “Serial Load” as described in “Updating Nonredun-
dant Systems.”

5.

Type y and press Enter. A message appears asking you to wait
while the update loads.

The update loads to the standby card. A minor alarm is reported be-
cause the active and standby cards now have different software ver-
sions.

MIX 56 by Telect MIX 56 Directory (Ctrl+D)

Help (?)

Update Flash

------------

TFTP Ethernet Port:

-------------------------------------------------------------------------------

Filename: mix56tst

TFTP Host IP Address: 10. 2. 1. 75

[TFTP Load]

Serial Port: (9-pin)

-------------------------------------------------------------------------------

[Serial Load]

Transfer Program to Standby Card:

-------------------------------------------------------------------------------

[Program Transfer]