4 Software Operation

MIX 56 User Manual

4-20

Telect, Inc. 122188-10 A0

Step

Action

1.

From the Directory screen, press 6 to select High Speed Configura-
tion, then Enter.

The High Speed Configuration screen appears.

2.

In the Name field, type a name for the DS3 circuit (up to 16 charac-
ters) and press Enter.

3.

Tab to the Clock Source field, select a clock source by pressing the
spacebar to toggle between DS3 Loop Timing and Internal, and
then press Enter.

◊ DS3 Loop Timing—Timing is recovered from the incoming

DS3 signal.

◊ Internal—Timing is generated by the onboard Stratum 4 clock.

NOTE

In DS3 networks, one network element provides master timing,
while the other one recovers timing from the incoming DS3 signal.

4.

Tab to the Mode field, select a DS3 mode by pressing the spacebar
to toggle between M13 and C-bit, and then press Enter.

MIX 56 by Telect MIX 56 Directory (Ctrl+D)

Help (?)

High Speed Configuration

------------------------

Name: High Speed

Clock Source: DS3 Loop Timing

Mode: M13

Optional C-bit LAPD Information

-------------------------------

Local Remote

--------------------------------- -------------------------------

Equipment ID:

Location ID:

Frame ID:

Unit ID:

Facility ID - Local:

Facility ID - Remote:

[Apply]