4 Software Operation

MIX 56 User Manual

4-34

Telect, Inc. 122188-10 A0

3.

To clear the error counts for all 96 periods, tab to the [Clear] button
and press Enter. This also clears the High Speed 24-hour counts.

A prompt appears asking you to confirm the clear.

4.

Type y and press Enter.

To View High-Speed Errors in 24-Hour Histories

The High Speed Errors-24 hr. screen updates every 15 minutes, displaying
DS3 error counts for two time periods: from Midnight the current day to
the end of the last completed 15-minute period and from Midnight the pre-
vious day to one second before Midnight the current day. When finished
viewing the error counts, you can clear both periods at once.

NOTE

During the first 15-minute period of the day (between 00:00:00 and
00:14:59) no error counts are shown in the 24-hour history screen. Howev-
er, you still can see error counts during this first 15-minute period by going
to the High Speed Errors-15 min. screen.

Step

Action

1.

From the Directory screen, type 12 to select High Speed Errors-24
hr. and press Enter. The High Speed Errors-24 hr. screen appears:

2.

To clear both periods, tab to the [Clear] button and press Enter. This
also clears the High Speed 15-minute error counts.

MIX 56 by Telect MIX 56 Directory (Ctrl+D)

Help (?)

High Speed Errors-24 hr.

------------------------

[Clear]

CURRENT PREVIOUS

Span: 00:00:00-23:29:59 Span: 00:00:00-23:59:59

----------------------- -----------------------

ES: 00001 ES: 00001

SES: 00001 SES: 00001

CV: 00000 CV: 00000

LOSS: 00001 LOSS: 00000

AISS: 00002 AISS: 00000

FC: 00003 FC: 00000

Advertising