background image

4 Software Operation

MIX 56 User Manual

4-52

Telect, Inc. 122188-10 A0

NOTE

The DS3 test on the high speed line is a C-Bit DS3 signal. This is
due to the capabilities of the DS3 framer chip we used not being
able to recognize a received test pattern unless the framer chip is
set for C-Bit.

3.

Tab to the “Pattern” field and select the desired pattern by pressing
the spacebar to toggle between the available options and then press-
ing Enter.

The available options depend on the mode selection and are speci-
fied in the previous table.

4.

Tab to the “Low Speed Channel” field and select the channel by
typing in the number of the desired channel and then pressing enter.

NOTE

This field is only available in the “T1/E1 Test on High Speed Line”

or “Unframed Test on Low Speed Line” modes.

If the selected Low Speed Channel is disabled or unavailable, then
the “Line Type:” display will change to either “Line Disabled” or
“Line Unavail.”

5.

Tab to the “Framed Signal” field and toggle between “yes” and
“no” by pressing the spacebar and then pressing Enter.

NOTE

This field is only available in the “T1/E1 Test on High Speed Line”
mode.

6.

Tab to the “Frame Format” field and toggle between the available
options by pressing the spacebar and then pressing Enter. The avail-
able options depend on whether the line is a T1 or E1. The T1 op-
tions are “ESF” and “SF”. The E1 options are “DOUBLE” and
“MULTI”.

NOTE

This field is only available in the “T1/E1 Test on High Speed Line”
mode.

Advertising