Telect MIX 56 User Manual

Page 94

Advertising
background image

4 Software Operation

MIX 56 User Manual

4-48

Telect, Inc. 122188-10 A0

Settings screen is set to Yes. If loop back permission is set to Yes then
the MIX 56 will —
Go into loopback when the loop-up code is no longer received and

it had received the loop-up code for at least 5 seconds. A loopback
is not established until the loop-up code is no longer received after
being received for at least 5 seconds.

Go out of loopback when the loop-down code has been received for

5 seconds. A loopback is cancelled after receiving the loop-down
code for 5 seconds, it does not wait for the loop-down code to cease
being received.

The low-speed loop-up and loop-down codes can be received and
transmitted either via the individual DS1 channel of the MUXed DS3
signal or via the corresponding DS1 line. The MIX 56 can be set up to
either the DS3 or DS1 direction but not both at the same time. The low-
speed remote loopback direction, DS3 or DS1, is set by the “LS Remote
LB Dir” field of the System Settings screen.
“LS Remote LB Dir” set for DS3 (default): The loop-up and

loop-down codes are received and transmitted on the corresponding
DS1 channel of the MUXed DS3 signal. The loopback set on re-
ceiving the loop-up code is the low-speed local loopback. A loop-
up or loop-down code received on the DS1 line is not recognized.

“LS Remote LB Dir” set for DS1: The loop-up and loop-down

codes are received and transmitted on the corresponding DS1 line.
The loopback set on receiving the loop-up code is the low-speed
line loopback. A loop-up or loop-down code received from the cor-
responding DS1 channel of the DS3 signal is not recognized.

To run a loopback, proceed as follow:

Step

Action

1.

From the Directory screen, press 19 to select Loopbacks, then En-
ter.

The Loopbacks screen appears:

Advertising