Telect MIX 56 User Manual

Page 33

Advertising
background image

MIX 56 User Manual

2 Installation

122188-10 A0

Telect, Inc.

2-11

3.

Connect two 75 ohm BNC cables to the connectors marked DS3 In
and DS3 Out, as shown below.

4.

Connect an RJ-45 cable to the Ethernet port, as shown below.

NOTE

If you are connecting the MIX 56 to an Ethernet Hub, use a “straight”
Ethernet cable. If you are connecting directly to a Network Management
System (NMS) PC, use a “crossover” Ethernet cable.

Configure the network port as half duplex to match the MIX 56 Ethernet
port.

5.

Connect external alarms to the Critical, Major, and Minor alarm
contacts by pressing and holding the spring clip, inserting the wire,
and then releasing the spring clip.

See the illustration on the next page.

Type of Ground

Switch Position

Definition

Logic

(M13 Card Circuitry)

On (Default)

Connected to chassis ground

Off

Not connected to chassis ground

DS3 Coaxial Shield

Tx

On (Default)

Connected to chassis ground

Off

Not connected to chassis ground

DS3 Coaxial Shield

Rx

On (Default)

Connected to chassis ground

Off

Not connected to chassis ground

+B

–B

+A

–A

+B

–B

+A

–A

75 ohm BNC

Connectors

RJ-45 Ethernet Cable

Advertising