Low-speed configuration screen, Alarm thresholds screen, System interfaces screen – Telect MIX 56 User Manual

Page 54

Advertising
background image

4 Software Operation

MIX 56 User Manual

4-8

Telect, Inc. 122188-10 A0

Low-Speed Configuration Screen

* Type is an inactive field when “Signal Type” is “T1.” To active this field “Signal Type” must be changed to

“Mixed, T1’s and E1’s.”

Alarm Thresholds Screen

These setting values are specified in Telcordia GR-820-CORE.

* This is not an active field; it only displays whether redundancy switching is “Normal” (allowed to switch) or

“Locked” (redundancy switching is not allowed).

System Interfaces Screen

Field

Default Setting

Channel #

“1”

Name

“Low Speed 01”

Type

T1

*

Interface

NI

Line Code

“B8ZS”

Line Build Out

“0–110 ft”

State

“Disabled”

Field

Default Setting (sec)

AIS, LOS, RAI, and OOF Alarm On

“002”

AIS, LOS, RAI, and OOF Alarm Off

“003”

Low Speed ES-15 min. Alarm On

“065”

Low Speed ES-24 hr. Alarm On

“648”

Low Speed SES-15 min. Alarm On

“010”

Low Speed SES-24 hr. Alarm On

“100”

High Speed ES-15 min. Alarm On

“025”

High Speed ES-24 hr. Alarm On

“250”

High Speed SES-15 min. Alarm On

“004”

High Speed SES-24 hr. Alarm On

“040”

Redundancy Switch Status

“Normal”

*

Field

Default Setting

Baud Rate

“9600”

Modem Detect

Disabled

SNMP Read Name

“public”

SNMP Write Name

“private”

SNMP Trap Name

Blank

SNMP Event Traps

Enabled

Ping Address

“0.0.0.0”

IP Address

“0.0.0.0”

Subnet Mask

“0.0.0.0”

Gateway

“0.0.0.0”

Trap 1, 2, 3, 4, 5, 6

“0.0.0.0”

Duplex

“half”

Advertising