Each terminal socket is equipped with two LEDs for displaying the line
status. Each of the line connectors labelled “to DTE” and “to DCE” are
assigned two LEDs. These display the line status as shown in the following
table.

Table A–24: Line status: V./X. interface module

S0

S1

Meaning

on

on

While booting: Reset of the interface

off

off

After booting: Port not in operation

alternating
with S1

alternating
with S0

Port initialized. No adapter cable connected (operational
state)

on

off

Port initialized. Adapter cable connected (operational
state)

on

on

Port initialized. Data traffic is possible (operational state):

Case 1:
– with V.35 or V.24 cable to DTE
– receiver ready
– line status Data Terminal Ready has been reached

Case 2:
– with V.35 or V.24 cable to DCE
– and receiver ready
– line status Data Set Ready has been reached

Case 3:
– with X.21 cable to DTE
– and receiver ready
– if line status Control has been reached

Case 4:
– with X.21 cable to DCE
– receiver ready
– if line status Indication has been reached