Basic Configuration via Browser Interface

Trango Broadband Wireless — Access5830 User Manual Rev. F

page 18


Using this page the user can immediately see which SUs have associated. In the page shown, SU ID# 107 is associated,
and SU IDs 11, 22, 33, and 44, are not. Consider "Power Off" status synonymous with "not associated."

Power leveling takes place automatically every time an SU associates, so in most cases it is not necessary to manually run
power leveling. A thorough explanation of this feature is in the Configuration section.

RF Link Loopback Test

This is the built-in performance test. Specify an SU ID and
time in minutes to conduct the test. The test is prioritized, so
it will take precedence over all other traffic. 1600 byte
packets are sent and received between the SU and AP at 50
millisecond intervals over the time specified. The success
rate, and number of packets received, in bytes, is reported for
SU and AP.

SU Ranging / RSSI Test

Reports the distance from AP in miles,
SU TX Power, SU temperature, and the
received signal strength for uplink and
downlink for the specified SU. Use a
link budget calculator to analyze results.