Trango Broadband Access5830 User Manual

Page 68

Advertising
background image

Management

Trango Broadband Wireless — Access5830 User Manual Rev. F

page 64

M5300S-FSU:

Max:

+15

dBm

+/-

2

dB

Min:

-12

dBm

+/-

2

dB

EIRP

Max:

M5800S-FSU:

+36

dBm

M5800S-FSU-D:

+46 dBm (with AD5800-25-D Reflector)

M5300S-FSU:

+30

dBm


Freq. Stability:

.00025 % PLL stabilized (2.5 ppm) over temp

Freq. Plan:

Single upconversion, 480 MHz IF

Modulated BW:

22 MHz (null to null, 20 dB)

2

nd

Harmonic atten:

Per CFR47 part 15.205

LO Supression:

Per CFR47 part 15.205

Symbol

Rate:

1.375

MSPS

Error

Correction: None

Modulation:

1 Mbps DBPSK for header, 11 Mbps CCK spread spectrum for payload


Receiver Section (check these figures)
Cascade Noise Figure:

< 6 dB

Sensitivity:

- 82 dBm typical-1600 byte packet

(1E10-6 BER)

- 87 dBm typical-64 byte packet

Adj. Channel Rejection:

> 20 dB for 10 % PER

Image Rejection:

> 60 dB for 10% PER

Frequency Plan:

Single conversion, IF at 480 MHz

LO stability:

.00025% PLL stabilized (+/-2.5ppm) over temperature range


Data Input Section
Data Rate (User):

Up to 10 Mbps sustained throughput

Format:

10/100

BaseT

IEEE

802.3

Ethernet

compliant

Ethernet packet:

Up to 1600 byte long packets


Power
Input Voltage:

Input voltage range at unit is 10.5 VDC to 24 VDC max


Power is supplied over Ethernet cable using junction box provided, with up to 300 feet of 24 AWG STP cable.

Current Cons.:

400 mA in transmit mode at max power using 20 V standard adapter (8 W)

Data Output Section
Data Rate (User):

10 Mbps maximum sustained throughput

Format:

10/100

BaseT

IEEE

802.3

Ethernet

compliant

Ethernet Protocols:

TCP/IP, Telnet, TFTP, UDP, and HTTP


Physical Interfaces
LAN

Interface:

Shielded

RJ45

connector

Power:

Carried on 4 unused pins of Ethernet cable


Mechanical and Environmental
General Material:

High Temp ABS/Polycarbonate Enclosure

Size:

9.2”x4.25”3.1”

Weight:

1.5

lb

(radio)

Mounting:

Polycarbonate

Wall/Pole

mount

bracket


Environmental
Operating

Temp: -40

° to 60° C

Storage:

-40

° to 85° C

Humidity:

100

%

when

sealed

properly

NEMA

Rating:

NEMA

4

Advertising