Chapter 2 specifications – TDK GENESYS 1500W User Manual

Page 17

Advertising
background image

83-507-013 Rev. D

9

CHAPTER 2 SPECIFICATIONS

2.1 OUTPUT RATING

MODEL

GEN

6-100

8-90

12.5-60

20-38

30-25

40-19

60-12.5 80-9.5 100-7.5

150-5

300-2.5 600-1.3

1.Rated output voltage (*1)

V

6

8

12.5

20

30

40

60

80

100

150

300

600

2.Rated output current 750W (*2)

A

100

90

60

38

25

19

12.5

9.5

7.5

5

2.5

1.3

3.Rated output power 750W

W

600

720

750

760

750

760

750

760

750

750

750

780

MODEL

GEN

6-200

8-180

12.5-120

20-76

30-50

40-38

50-30

60-25

80-19

100-15 150-10

300-5 600-2.6

1.Rated output voltage (*1)

V

6

8

12.5

20

30

40

50

60

80

100

150

300

600

2.Rated Output Current 1500W (*2)

A

200

180

120

76

50

38

30

25

19

15

10

5

2.6

3.Rated output power 1500W

W

1200

1440

1500

1520

1500

1520

1500

1500

1520

1500

1500

1500

1560

2.2 INPUT CHARACTERISTICS

V

6

8

12.5

20

30

40

50

60

80

100

150

300

600

1. Input voltage/freq. (*3)

2. Input current (at 100/200Vac)

A

3. Power Factor

4. 750W models Efficiency (*4)

%

76/78

77/80

81/84

82/85

82/85

83/87

83/87

83/87

83/87

83/87

83/87

83/87

83/87

5. 1500W models Efficiency (*4)

%

77/79

78/81

82/85

83/86

83/86

84/88

84/88

84/88

84/88

84/88

84/88

84/88

84/88

6. Inrush current at 100/200V

A

2.3 CONSTANT VOLTAGE MODE

V

6

8

12.5

20

30

40

50

60

80

100

150

300

600

1. Max.Line regulation (*5)

2. Max.Load regulation (*6)

3. Ripple and noise (p-p,20MHz) (*10)

mV

60

60

60

60

60

60

60

60

80

80

100

150

300

4. Ripple r.m.s., 5Hz~1MHz (*10)

mV

8

8

8

8

8

8

8

8

8

8

10

25

60

5. Temperature coefficient

PPM/°C 100PPM/°C of rated output voltage, following 30 minutes warm up

6. Temperature drift

7. Rem. Sense compensation/wire

V

1

1

1

1

1.5

2

2

3

4

5

5

5

5

8. Up-prog. Response time 0~Vomax (*9)

mS

250

9. Down-prog. Response time: Full load

mS

10

250

No load

500

600

700

800

900

1000

1100

1100

1200

1500

2000

2500

4000

10. Transient response time

mS

11. Hold-up time

mS

2.4 CONSTANT CURRENT MODE

V

6

8

12.5

20

30

40

50

60

80

100

150

300

600

1. Max.line regulation (*5)

2. Max.load regulation (*7)

3. Ripple r.m.s. 5Hz~1MHz.750W (*8)

mA

200

180

120

76

63

48

38

29

23

18

13

8

1500W (*8)

mA

400

360

240

152

125

95

75

75

57

45

35

25

12

4. Temperature coefficient

PPM/°C

5. Temperature drift

2.5 ANALOG PROGRAMMING AND MONITORING

1.Vout voltage programming

2. Iout voltage programming

3. Vout resistor progrmming

4. Iout resistor programming

5. On/off control

6. Output current monitor

7. Output voltage monitor

8. Power supply OK signal

9. Parallel operation

10. Series operation

11. CV/CC inicator

12. Enable/Disable

13. Local/Remote analog control

14. Local/remote analog indicator

Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V.
By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local.

Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA.

4~5V-OK, 0V-Fail, 500ohm series resistance.
Possible, up to 4 units in master/slave mode with single wire current balance connection.

Possible (with external diodes), up to 2 units.
CV: TTL high (4~5V), source current: 10mA, CC: TTL low (0-0.6V). Sink current: 10mA .

Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated

By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.

0~5V or 0~10V, user selectable. Accuracy: 1%
0~5V or 0~10V, user selectable. Accuracy: 1%

100PPM/°C from rated output current, following 30 minutes warm-up.
0.05% of rated lout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.

output current.

Output set-point: 10~100%.
Less than 1mS for models up to and including 100V; 2mS for models above 100V.

85~265Vac continuous, 47-63Hz, single phase.

10.5/5 for 750W model, 21/11 for 1500W models.
0.99@100/200Vac, rated output power.

Less than 25A for 750W models, 50A for 1500W models.

0.01% of rated output voltage +2mV

0.01% of rated output voltage +2mV

0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.

50

80

150

80

150

More than 20mS, 100Vac, rated output power.

0.01% of rated output voltage +2mA
0.02% of rated output current +5mA

0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-0.5% of rated Vout.

0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1% of rated Vout.

0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1.5% of rated Iout.

Advertising