Table 7-3. SINGLE BYTE COMMUNICATIONS

Name

Bit Positions

Response

Description

Global

Commands

Disable MD Mode

1010 0000

None

Set supplies out of MD Mode (default)

Enable MD Mode

1010 0001

None

Set supplies into MD Mode

Disable SRQ

retransmission

1010 0010

None

Disable retransmission of SRQs by
supplies (default)

Enable SRQ

retransmission

1010 0011

None

Enable retransmission of SRQs by
supplies

Enable FLT Bit

1010 0100

None

Enable the FLT bit in the SENA

Reg-

ister

Disconnect serial

communications

1011 1111

OK

All supplies will halt transmission and
enter the non-addressed state.

Addressed

Commands

Read Registers

100x xxxx

Register data

Non destructive read of all register. x
xxxx is the address of the supply in
binary.

Re-enable SRQ

Byte 1

1010 0101

Byte 2

xxxx xxxx

None

Re-enable SRQ without reading or
clearing the SEVE Register. xxxx xxxx
is the address of the supply in binary.
Works only in MD Mode.

Print Power On

Time

Byte 1

1010 0110

Byte 2

xxxx xxxx

Power On time

in minutes

Read the time the supply is active un-
der AC Power. xxxx xxxx is the ad-
dress of the supply in binary. Returns a
32 Bit integer as 8 Hex bytes. A ‘$’
sign is appended to the data followed
by a 2 byte check-sum. A total of 11
bytes are returned.

Retransmit last

message

110x xxxx

Last message

Retransmit last response from a com-
mand. x xxxx is the address of the
supply in binary.

Acknowledge

SRQ

111x xxxx

None

Acknowledge SRQ. If retransmission
of SRQ is enabled, it will remain en-
abled for the next SRQ. X xxxx is the
address of the supply in binary.

Test if MD Mode

is Installed

Byte 1

1010 1010

Byte 2

xxxx xxxx

0 or 1

Returns a 0 if not installed or a 1 if in-
stalled. A ‘$’ sign followed by a 2 bytes
checksum and Carriage Return is ap-
pended to the data. xxxx xxxx is the
address of the supply in binary.

Supply Initiated

Communications

SRQ

100x xxxx

N/A

SRQ from supply when in MD Mode. X
xxxx is the address of the supply in
binary.

Advertising