TDK GENESYS 1500W User Manual

Page 55

Advertising
background image

83-507-013 Rev. D

47

6.5 RESISITIVE PROGRAMMING OF OUTPUT VOLTAGE AND CURRENT LIMIT

For resistive programming, internal current sources, for Output Voltage and/or Output Current control,
supply 1mA current through external programming resistors connected between J1-9 & 22 and J1-10
& 23. The voltage across the programming resistors is used as a programming voltage for the power
supply. Resistance of 05Kohm or 010Kohm can be selected to program the Output Voltage and
Output Current from zero to full scale.
A variable resistor can control the output over its entire range, or a combination of variable resistor
and series/parallel resistors can control the output over restricted portion of its range.

Perform the following procedure to set the power supply to Resistive programming:
1. Turn the AC On/Off switch to Off.
2. Set setup switch SW1, positions 1 and 2 to their UP position.
3. Set SW1, position 3 to select the programming resistor range according to Table 6-4.
4. Set SW1, positions 7 and 8 to their UP position, to enable resistive programming mode.
5. Connect a wire jumper between J1-8 and J1-12 (refer to Table 4-4).
6. Connect the programming resistors to the mating plug of J1 as shown in Fig.6-2.
7. Set the programming resistors to the desired resistance and turn the power supply ON. Adjust the

resistors to change the power supply output.

NOTES:
1. SW1, positions 4, 5, 6 and 9 are not required for remote programming. Their settings can be de-

termined according to the application requirements.

2. The control circuits allow the user to set the Output Voltage and Output Current up to 5% over the

model-rated maximum value. The power supply will operate within the extended range, however it
is not recommended to operate the power supply over its voltage and current rating and perform-
ance is not guaranteed.

3. To maintain the temperature stability specification of the power supply, the resistors used for pro-

gramming should be stable and low noise resistors, with temperature coefficient of less than
50ppm.

4. When resistive programming is used, front panel and computer control (via serial communication

port) of Output Voltage and Current are disabled.

Table 6-4: SW1-3 setting and programming range

SW1-3 setting

Output Voltage programming

VPGM (J1-9)

Output Current programming

IPGM (J1-10)

UP

0-10Kohm

0-10Kohm

DOWN

0-5Kohm

0-5Kohm

1

14

13

25

10

9

23

22

OUTPUT CURRENT

PROGRAMMING

OUTPUT VOLTAGE

PROGRAMMING

J1 connector, rear panel view

Fig.6-2: Remote resistive programming

PROGRAMMING

RESISTOR

PROGRAMMING

RESISTOR

OPTIONAL SETS

LOWER LIMIT

OPTIONAL SETS

LOWER LIMIT

OPTIONAL SETS

UPPER LIMIT

OPTIONAL SETS

UPPER LIMIT

12

8

Advertising