NOTES:
*1: Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage.
*2: Minimum current is guaranteed to maximum 0.4% of the rated output current.
*3: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be de-

scribed as 100-240Vac (50/60Hz).

*4: At 100/200V input voltage and maximum output power.
*5: From 85132Vac or 170265Vac, constant load.
*6: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote
Sense.
*7: For load voltage change, equal to the unit voltage rating, constant input voltage.
*8: For 6V models the ripple is measured at 26V output voltage and full output current. For other
models, the ripple is measured at 10100% output voltage and full output current.
*9: With rated, resistive load.

*10. For 6300V models: Measured with JEITA RC-9131A (1:1) probe

For 600V model: Measured with (10:1) probe.

2.12 SUPPLEMENTAL CHARACTERISTICS
The supplemental characteristics give typical but non-warranted performance characteristics. The
supplemental characteristics are useful in assessing applications for the power supply. Several kinds
of supplemental characteristics are listed below.

1. Evaluation Data: Typical performance of the power supply.
2. Reliability Data: Reliability Performance of the power supply.
3. IEC1000 Data: Performance of the power supply under IEC1000 test conditions.
4. EMI Data: Typical EMI (conducted and radiated) performance of the power supply.

The supplemental characteristics data is held in each TDK-Lambda Americas Inc. sales and service
facility. For further details please contact the TDK-Lambda Americas Inc. office nearest you.