66

3. Status Enable Register
The Status Enable Register is set by the user to Enable SRQs for changes in power supply status.

Table 7-12: Status Enable Register

BIT

Status name

Status symbol

Bit Set condition

Bit reset condition

0 (LSB)

Constant Voltage

CV

1

Constant Current

CC

2

No Fault

NFLT

3

Fault active

FLT

User command:
“SENA nn” is
received, where
nn is hexadecimal
bits.

User command: “SENA nn”
is received, where nn is
hexadecimal bits.
If “nn”=00, no SRQ is sent
when there is a change in
Status Condition Register.

4

Auto-Restart enabled

AST

Always zero

Always zero

5

Fold enabled

FDE

Always zero

Always zero

6

Spare

Spare

Always zero

Always zero

7 (MSB)

Local Mode

LCL

“SENA nn”

command

“SENA nn”

command

4. Status Event Register
The Status Event Register will set a bit if a change in the power supply status occurs and it is en-
abled. The register is cleared when the “SEVE?” or “CLS” commands are received. A change in this
register will generate SRQ.

Table 7-13: Status Event Register

BIT

Status name

Status symbol

Bit Set condition

Bit reset condition

0 (LSB)

Constant Voltage

CV

1

Constant Current

CC

2

No Fault

NFLT

3

Fault active

FLT

Changes in status
occur and it is
Enabled.
The change can
set a bit, but when
the change clears
the bit remains
set.

4

Auto-Restart enabled

0

Always zero

5

Fold enabled

0

Always zero

6

Spare

0

Always zero

7 (MSB)

Local Mode

LCL

Unit is set to Local
by pressing front
panel REM/LOC
button.

Entire Event Register is
cleared when user sends
“SEVE?” command to read
the register.
“CLS” and power-up also
clear the Status Event
Register.

Advertising