TDK GENESYS 1500W User Manual

Page 63

Advertising
background image

83-507-013 Rev. D

55

7.8.3

Initialization Control Commands

#

Command

Description

1

ADR n

ADR is followed by address, which can be 0 to 30 and is used to access the
power supply.

2

CLS

Clear status. Sets FEVE and SEVE registers to zero (refer to Section 7-11).

3

RST

Reset command. Brings the power supply to a safe and known state:
Output voltage: zero,

Remote: non-lockout remote,

Output current: zero,

Auto-start: Off,

Output: Off,

OVP: maximum,

FOLD: Off,

UVL: zero

The conditional registers (FLT and STAT) are updated, the other registers are
not changed.

4

RMT

Sets the power supply to local or remote mode:
1.

RMT 0 or RMT LOC, sets the power supply into Local mode.

2.

RMT 1 or RMT REM, sets the unit into remote mode.

3.

RMT 2 or RMT LLO, sets the unit into Local Lockout mode (latched remote mode).

5

RMT?

Returns to the Remote mode setting:
1. “LOC” - The unit is in Local mode.
2. “REM” - The unit is in Remote mode.
3. “LLO” - The unit is in Local Lockout (latched remote) mode.

6

MDAV?

Returns MD MODE OPTION Status. 1 indicates installed and 0 indicates not in-
stalled.

7

\

Repeat last command. If \<CR> is received, the power supply will repeat the last
command.

7.8.4

ID Control Commands

#

Command

Description

1

IDN?

Returns the power supply model identification as an ASCII string:

LAMBDA, GENX-Y

2

REV?

Returns the software version as an ASCII string.

3

SN?

Returns the unit serial number. Up to 12 characters.

4

DATE?

Returns date of last test. Date format: yyyy/mm/dd

7.8.5

Output Control Commands

#

Command

Description

1

PV n

Sets the output voltage value in Volts. The range of voltage value is described in
Table 7-5. The maximum number of characters is 12. See the following examples
for PV n format: PV 12, PV 012, PV 12.0, PV 012.00, etc…

2

PV?

Reads the output voltage setting. Returns the string “n” where “n” is the exact
string sent in the PV n command. When in Local mode, returns the PREVIEW
(front panel) settings in a 5 digit string.

3

MV?

Reads the actual output voltage. Returns a 5 digits string.
Example: 60V supply sends 01.150, 15.012, 50.000, etc…

4

PC n
(See

Note 1)

Set the Output Current value in Amperes. The range of current values is de-
scribed in Table 7.6. The maximum number of characters is 12. See the following
examples for PC n format: PC n format: PC 10, PC 10.0, PC 010.00, etc…

5

PC?

Reads the Output Current setting. Returns the string “n” where “n” is the exact
string sent in the PC n command. When in Local mode, returns the PREVIEW
(front panel) settings in a 5 digit string.

6

MC? (See
Note 2)

Reads the actual Output Current. Returns a 5 digit string.
Example: 200A supply sends 000.50, 110.12, 200.00, etc…