CHAPTER 4 FRONT AND REAR PANEL CONTROLS AND CONNECTORS

4.1 INTRODUCTION

The Genesys

TM

Power Supply series has a full set of controls, indicators and connectors that allow the

user to easily setup and operate the unit. Before starting to operate the unit, please read the following
Sections for explanation of the functions of the controls and connectors terminals.
-Section 4.2: Front Panel Controls and Indicators.
-Section 4.3: Rear Panel Connections and Controls.

4.2 FRONT PANEL CONTROLS AND INDICATORS

See Fig.4-1 to review the controls, indicators and meters located on the power supply front panel.

Table 4-1: Front Panel controls and indicators

Number

Control/Indicator

Description

Section

1

VOLTAGE control

High resolution rotary encoder for adjusting the Output
Voltage. Also adjusts the OVP/UVL levels and selects the
Address

5.2.1
5.3.1
5.4.1
7.2.2

2

VOLTAGE indicator

Green LED, lights for constant-Voltage mode operation.

3

VOLTAGE display

4 digit, 7-segment LED display. Normally displays the Out-
put Voltage. When the PREV button is pressed, the display
indicates the programmed setting of the Output Voltage.
When the OVP/UVL button is pressed, the Voltage display
indicates the OVP/UVL setting.

Fig.4-1: Front panel controls and indicators

VOLTAGE

ALARM

FINE

PREV/

OVP
UVL

FOLD

REM/LOC OUT

DC AMPS

CURRENT

DC VOLTS

POWER

1

14

17

18

19

2

15

16

3

13

10

4

11

5

12

9

6

7

8

Advertising
This manual is related to the following products: