6 print menu, Cw-11 indicator – Ohaus CW-11 Indicator User Manual

Page 21

Advertising
background image

18

CW-11 Indicator

2.8 Initial Scale Setup (Cont.)

2.8.6 Print Menu

The Print menu provides data communication settings which can be entered. It contains 9 submenus: Reset,
Baud rate, Parity Bit, Data Length, Stop Bits, Auto Print, Interval, Stable and Save.

Procedure

PRINT
To select any of the items in the Print menu, proceed
as follows: NOTE: If you have entered from the
preceeding menu, disregard the first step.

With the Indicator ON, press and hold the G/N/T/
MENU button until MENU is displayed. When you
release the G/N/T/MENU button, CAL is displayed,
then press PRINT/UNITS button, until Print is dis-
played.

RESET

Press G/N/T/MENU button, rESEtn is displayed. This
allows resetting the Print menu to factory defaults.
rESETn = no does not reset settings. rESETy= yes
will reset the entire Print menu as follows:
Baud rate =2400, parity =none, data length=7,
stop bit=2.

Press PRINT/UNITS button, and select N or Y.

BAUD RATE

Press G/N/T/MENU button, bd2400 displayed.

Press PRINT/UNITS button, and select desired baud
rate. Baud rate selections are: 1200, 2400, 4800
9600 and 19200. 2400 is the default setting.

PARITY

Press G/N/T/MENU button, PAr NO is displayed.
This is the parity bit.

Press PRINT/UNITS button, and select desired parity
of NO=none, Odd=odd, E=even. Default setting is
none.