3 technical data, 1 data, Technical data – VEGA VEGASON 51K…53K User Manual

Page 17

Advertising
background image

VEGASON 51K … 53K

17

0

4

22 mA

14

36

V

29

16

Technical data

3 Technical data

3.1 Data

Power supply

Supply voltage
- four-wire sensor

230 V AC (20 … 250 V AC), 50/60 Hz
24 V DC (20 … 72 V DC)
fuse 0,2 A TR

- two-wire sensor

24 V DC (16 … 36 V DC); Sicherung 0,2 A TR

1000

900

800

700
680

600

500

400

300

250

200

100

0

16

20

25

30

35

17

18

19

29

36

V

max. voltage limit
with not-Ex-sensors

max. voltage
limit with
Ex-sensors

HART

®

-

load

Diagram of the min. supply voltage dependent on the
sensor current (two-wire sensor)

Current consumption
- two-wire sensor

max. 22,5 mA

- four-wire sensor

max. 140 mA

Power consumption
- two-wire sensor

max. 80 mW, 0,45 VA

- four-wire sensor

max. 1,2 W, 2,50 VA

Load
- four-wire sensor

max. 500

- two-wire sensor

see diagram

Load diagram of the two-wire sensor
(loop resistor of processing unit, e.g. DCS and supply line)

Range of the required and permis-
sible terminal voltage

Ex-voltage limit

min. voltage limit
by using the
HART

®

-load

Advertising