VEGASON 51K … 53K

35

Mounting and installation

Correct and wrong length of socket piece

Wrong

Correct

Reference plane

>

60 mm

Socket piece too long

When mounting the sensor in a socket piece
which is too long, strong false echoes are
caused, aggravating the measurement.
Please ensure that the transducer protrudes
at least 30 mm out of the socket piece.