VEGASON 51K … 53K

Technical data

Type

51…

52…

53…

Measuring range (relating to the transducer surface)

Liquid

0,25 … 4 m

0,4 … 7 m

0,6 … 15 m

Solid

0,30 … 2 m

0,5 … 3,5 m

0,75 … 7 m

Output signal

Analogue 4 … 20 mA-current signal

Adjustment

- PC with adjustment software VEGA Visual Operating
- adjustment module MINICOM
- HART

®

-handheld

Accuracy (typical values under reference conditions)

1)

Class accuracy (deviation in characteristics
including repeatability and hysteresis
acc. to the limit point method)

< 0,1 % relating to max. measuring range

Temperature drift (relating to 20°C)

< 0,015 %/10 K of measuring range

Accuracy of the 4 … 20 mA-
output signal

0,025 % (D/A-converter)

Resolution

1 mm

Characteristics

Min. span
(between empty and full adjustment)

> 20 mm (recommended > 50 mm)

Ultrasonic frequency

70 kHz

55 kHz

34 kHz

Intervals

1,0 s

1,0 s

1,0 s

Beam angle
(at -3 dB emitted power)

5,5°

5,5°

Response time

2)

2 … 20 s
(dependent on the factory setting)

Materials

Housing

PBT (Valox)

Transducer, process connection thread

PVDF

Compression flange

PP or 1.4571

Transducer diaphragm (type 53)

1.4571

Weights

Weight incl. transducer
- VEGASON 51

1,2 kg

- VEGASON 52

1,6 kg

- VEGASON 53

2,3 kg

1)

Reference conditions acc. to IEC 770, e.g.: Temperature 18°C … 30°C etc.

2)

The response time is the time the sensor requires to provide the level correctly with a quick level change
(with max. 10 % deviation).