VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol Approval according to LPR radio standard User Manual

Page 67

Advertising
background image

l

1 x closing cap ½ NPT, 1 x blind stopper
½

NPT, 1 x blind stopper M16 x 1.5 or

optionally

7)

1 x plug M12 x 1 for external

indicating and adjustment unit

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally

8)

1 x plug M12 x 1 for external

indicating and adjustment unit

Spring-loaded terminals for wire cross-section

-

Massive wire, cord

0.2 … 2.5 mm² (AWG 24 … 14)

-

Stranded wire with end sleeve

0.2 … 1.5 mm² (AWG 24 … 16)

-

Two stranded wires with double end
sleeve, each

0.2 … 1.5 mm² (AWG 24 … 16)

Indicating and adjustment module

Voltage supply and data transmission

through the sensor

Indication

LC display in dot matrix

Measured value indication

-

Number of digits

5

-

Size of digits

W x H = 7 x 13 mm (sensors with software ≥ 4.0.0,
hardware ≥ 2.0.0)
W x H = 5 x 8 mm (sensors with software ≤ 3.99,
hardware < 2.0.0)

Adjustment elements

4 keys

Protection rating

-

unassembled

IP

20

-

mounted into the sensor without cover

IP

40

Materials

-

Housing

ABS

-

Inspection window

Polyester foil

Integrated clock

Date format

Day.Month.Year

Time format

12 h/24 h

Time zone Ex factory

CET

Measurement electronics temerature

Resolution

1 °C (1.8 °F)

Accuracy

±

1 °C (1.8 °F)

7)

Only with Ex d version

8)

Only with Ex d version

VEGAPULS

62 • Approval according to LPR radio standard

67

10 Supplement

41722

-EN

-120706

Advertising