VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol Approval according to LPR radio standard User Manual

Page 75

Advertising
background image

Request:

Parameter

Length

Code/Data

Function Code

1 Byte

0x06

Start Address

2 Bytes

0x0000 to 0xFFFF

Number of Registers

2 Bytes

Data

Response:

Parameter

Length

Code/Data

Function Code

1 Byte

0x04

Start Address

2 Bytes

2*N

Register Value

2 Bytes

Data

FC8 Diagnostics

With this function code different diagnostic functions can be triggered or diagnostic values read out.

Request:

Parameter

Length

Code/Data

Function Code

1 Byte

0x08

Sub Function Code

2 Bytes

Data

N*2 Bytes

Data

Response:

Parameter

Length

Code/Data

Function Code

1 Byte

0x08

Sub Function Code

2 Bytes

Data

N*2 Bytes

Data

Implemented function codes:

VEGAPULS

62 • Approval according to LPR radio standard

75

10 Supplement

41722

-EN

-120706

Advertising