VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol Approval according to LPR radio standard User Manual
Page 68
Voltage supply
Operating voltage
8 … 30 V DC
Interpolation protection
Available
Electrical protective measures
Protection, depending on housing version
-
Plastic housing
IP
66/IP 67
-
Aluminium housing, stainless steel
housing - investment casting, stainless
steel housing - electro-polished
IP
66/IP 68 (0.2 bar)
9)
-
Aluminium and stainless housing, in-
vestment casting (optionally available)
IP
66/IP 68 (1 bar)
Overvoltage category
III
Protection class
III
Approvals
Instruments with approvals can have different technical data depending on the version.
That's why the associated approval documents of these instruments have to be carefully noted.
They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and
"
serial number search" as well as via "Downloads" and "Approvals".
9)
The prerequisites for maintaining the protection rating are a suitable cable
as well as correct mounting.
68
VEGAPULS
62 • Approval according to LPR radio standard
10 Supplement
41722
-EN
-120706