5.2.8 S4 Control method and slowdown mode in traveling movement application

The frequency converter can be parametrised for two different control methods. The control method options are
listed in the following table. The descriptions of the control methods are given in the section “Control methods”.

Digital inputs and the control method:

Terminal

Name

MS2

EP2

1

DI1

S1

S1

2

DI2

S2

S2

3

DI3

MS2

AP

4

DI4

S11/S21

S11/S21

5

DI5 *)

S12/S22

S12/S22

6

DI6

ES

ES

*) Note: As factory default DI5 is not in use. The stop limit signal shall be connected in series to direction signals
respectively.

Control signals:

S1

Drive command forward

S2

Drive command reverse

MS2

Multistep 2 frequency

AP

Acceleration command

S11

Slowdown limit forward

S12

Stop limit forward

S21

Slowdown limit reverse

S22

Stop limit reverse

ES

External stop, used for thermal protection of the motor

Switch S4 - 1

Control method

0

EP2

1

MS2

The switch model has one slowdown input DI4. There are two ways to handle the slowdown command and the
selection is made with switch S4-2. Alternatives are shown in the following table. As the slowdown limit switch
contact opens during running, the maximum speed is limited in the running direction.