12 quick guide for the switch interface – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster NXT Service Manual User Manual

Page 52

Advertising
background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

52/53

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

12 QUICK GUIDE FOR THE SWITCH INTERFACE

Start with these:

Then proceed with the following:

Switch S9

Motor

Nominal f

Nominal U

- 1

- 2

0

0

100Hz/120Hz

400 V / 460 V

0

1

80Hz

400 V

1

0

35Hz

400 V

Switch S1

Max driving frequency

-1 -2 -3 Motor 100/120 Hz Motor 80 Hz Motor 35 Hz

1

1

1

50

55

26

1

1

0

60

60

28

1

0

1

70

65

30

1

0

0

85

70

33

0

1

0

95

75

35

0

0

0

100

80

19

0

1

1

110

45

21

0

0

1

120

50

24

Switch S6

Zero f V

[%]

U/f Mid V

[%]

Motor Type

-1

-2

-3

0

1

0

6

12

MF06LA100

1

0

1

6.5

12

MF06LA100(*)

0

0

0

8

12

MF06LA200

1

1

0

8.5

12

MF06LA200(*)

0

1

1

9

16

MF06MA100

0

0

1

10

14

MF06MA200, MF06MK200

(100/120 Hz)

1

0

0

21

24

MF06MK200 (35Hz)

1

1

1

Chain hoist

(*) Boost function

Switch S7

Current limit

[%]

K003 [A]

K006 [A]

-1

-2

-3

0

1

0

150 %

3.6

7.7

Switch S2

Min driving frequency

-1 -2 -3 Motor 100/120 Hz Motor 80 Hz Motor f 35 Hz

0

1

1

-

24

-

0

0

0

14

10

5

0

0

1

16

12

6

1

0

1

20

14

7

1

0

0

23

20

8

0

1

0

26

18

9

1

1

0

28

16

10

1

1

1

30

22

-

Switch S8

Number of

Motors

K003 Current

[A

rms

]

K006 Current [A

rms

]

-1

- 2

- 3

0

0

0

1

3

3

0

0

1

2

4.8

6

0

1

0

3

-

9

0

1

1

4

-

12

Finally, set these:

Switch

S4-1

Switch

S4-2

Method

Operation

Description

0

EP2

1

MS2

0

Direction

memory ON

Limit switch status

saved.

1

Direction

memory

OFF

Max. speed limited in

both directions until

the circuit is closed.

S3

Acceleration

and

deceleration

Time

-1 -2 -3

1

1

0

1.5

0

1

1

2

0

1

0

2.5

1

0

1

3

0

0

0

3.5

1

0

0

4

0

0

1

4.5

1

1

1

5.5

Input

MS2

EP2

DI1

S1

S1

DI2

S2

S2

DI3

MS2

AP

DI4

S11/S21

S11/S21

DI5

SS12/S22

S12/S22

DI6

ES

ES

COM

Common DI1-DI6

Switch S10-1

DI6 (external stop)

Function

Description

0

In use

Voltage present in input.

1

Not in use

No effect in operation.

Switch

S5

Slowdown &Stop input function

- 1 - 2

Input DI4

(Slowdown)

Input DI5 (Stop) Slowdown f [%]

0

0

In use

In use

20

0

1

In use

Not in use

20

1

0

In use

In use

35

1

1

Not in use

Not in use

-