11 TECHNICAL DATA

Mains connection

Supply voltage U

in

380 - 480V, -15%...+10% 3-phase

Supply voltage frequency

45…66 Hz

Connection to mains

Once per minute or less (normal case)

Motor connection

Output voltage

0 — 0,95*U

in

Nominal output current

003: I

N

2.4A (max 3.6A), 006: I

N

5.6A (max 7.7A)

Continuous output current

Ambient temperature max. +50ºC, overload 1.5 x I

N

(1min/10min)

Starting current

2 x I

N

2 sec every 20 sec, if output frequency <30Hz and temperature

of heatsink <+60ºC

Output frequency

5…120 Hz (limited options)

Braking resistor (only 006

model)

Resistance

Internal resistor: 120

(45 W continuous, 2000 W peak power)

External resistor: 90

(550W continuous power)

Digital inputs

Control voltage

42 – 240 V

ac

, current consumption 15 ± 5 mA

Terminals

Tightening torque

0,5 – 0,6 Nm

Conductor diameter

Mains, motor, braking resistor and grounding terminals: 1.5 – 4.0 mm

Digital input terminals: 1.0 – 1.5 mm

Control features

Control method

Frequency Control U/f

Open Loop Vector Control

Switching frequency

3,6 kHz

Field weakening point

Fixed values

Acceleration time

1,5…5,5s (0,5s steps)

Deceleration time

1,5…5,5s (0,5s steps)

Ambient conditions

Ambient operating temperature

–10°C (no frost)…+50° C (outside the cubicle + 40˚C)

Storage temperature

–40°C…+70°C

Relative humidity

0…95% RH, non-condensing, non-corrosive, no dripping water

Air quality:

- Chemical vapors

- Mechanical particles

IEC 721-3-3, unit in operation, class 3C2

IEC 721-3-3, unit in operation, class 3S2

Altitude

100% load capacity (no derating) up to 1000m. 1% derating for each
100m above 1000m; max. 2000m

Vibration:

EN50178/EN60068-2-6

5...150 Hz

Displacement amplitude 1 (peak) mm at 5...15.8 Hz

Max acceleration amplitude 1 G at 15.8...150 Hz

Shock

EN50178, IEC 68-2-27

UPS Drop Test (for applicable UPS weights)

Storage and shipping: max 15 G, 11 ms (in package)

Enclosure class

IP20

Weight

003 model: 0.6 kg, 006 model: 1.4 kg (including braking resistor)

EMC

Immunity

Complies with EN61000-6-2, EMC: EN61800-3: 2004

Emissions

EMC-level N: with the internal EMC filter connected

EMC level 0: with the internal EMC filter disconnected

Complies with EN61800-3 A11 (2004) for second environment

Safety

61800-5-1, EN60204-1, CE, UL, cUL, FI, GOST R, IEC (see the unit’s
main sticker for more detailed approvals), RoHS

Protections

Over voltage protection

875V

DC

trip level

Under voltage protection

333V

DC

trip level

Earth-fault protection

Earth fault is tested before every start. In case of earth fault in motor
or motor cable, only the frequency converter Is protected.

Unit over temperature

Yes

Motor stall

Yes

Overcurrent protection

Trip limit 4,0*I

N

instantaneously

Motor overtemperature supervision

Yes