5.3.3 S7 Current limit on chain hoist lifting application

The frequency converter limits the maximum current. The limit settings for different currents are shown in the
following table. The settings are applicable to the model 003 only.

Switch S7

Current Limit

-1

-2

-3

Current Limit [%]

003 [A]

0

0

0

200

4.8

0

0

1

190

4.6

0

1

0

180

4.3

0

1

1

170

4.1

1

0

0

155

3.7

1

0

1

140

3.4

1

1

0

125

3.0

1

1

1

110

2.6