7 OPERATING INSTRUCTIONS

7.1

Normal function

7.1.1 Control methods

EP (Electronic Potentiometer) stepless pushbutton control

Released (stop):

The device doesn’t move or, if it is already moving, it will decelerate to a complete stop.

Fully pressed (accelerate):

The device accelerates continuously until the pushbutton is released or the maximum speed is
reached.

Half-pressed (slow/hold):

If half-pressed the device will accelerate until it reaches the preset slow speed.

If half-pressed when the device is moving above the preset slow speed, the current speed will be
held without accelerating or decelerating.

1 Pushbutton released: the motor does not turn

2 Pushbutton half-pressed: the motor accelerates until it reaches the preset slow speed

3 Pushbutton fully pressed: the motor accelerates towards maximum speed

4 Pushbutton half-pressed: the current speed is held

5 Pushbutton fully pressed: the motor accelerates until it reaches maximum speed

6 Pushbutton half-pressed: the current (maximum) speed is held

7 Pushbutton released: the motor decelerates

8 Pushbutton half-pressed: the current speed is held

9 Pushbutton released: the motor decelerates to a complete stop.