5 automatic connection of two parani10 units – SENA Parani10 User Manual

Page 24

Advertising
background image

24

1. Transition from ONLINE STATUS to STANDBY STATUS by entering ‘+++’

string to the Parani10.

Check the current Parani10 status by entering the

‘AT+BTINFO?’ command.

The Parani10 status should display CONNECT

STATUS.

2.Release the current Bluetooth connection by entering ‘ATH’command.

Once

disconnected successfully, the Parani10 returns the ‘DISCONNECT’message.

3.2.5 Automatic connection of two Parani10 Units

Two Parani10 units connect automatically when powered up.

For automatic

Parani10 connection first make a Bluetooth connection between two Parani10

units.

Once connected, the Parani10 stores the 48-bit BD_ADDR of its

counterpart.

To expedite 48-bit BD_ADDR input operation, the Parani10 is

designed to store the BD_ADDR of its latest counterpart.

1. Set one Parani10 to do INQUIRY SCAN and PAGE SCAN operation as

directed in section 3.2.3.

2. Set the other Parani10 to connect to the Parani10 in the previous step.

3. Once connected successfully, both Parani10 units store the BD_ADDR of

ATH

OK

DISCONNECT

+++

OK

AT+BTINFO?

000B530000A9, Parani10-0000A9,MODE0,CONNECT,0,0

OK

Advertising