SENA Parani10 User Manual

Page 41

Advertising
background image

41

D<cr><lf>

<cr><lf>OK<cr><lf>

5)

ATD112233445566<cr>

<cr><lf>OK<cr><lf>

<cr><lf>CONNECT

<cr><lf> or

<cr><lf>ERROR<cr

><lf>

Connect to the specified device.

If you want to enable Authentication

and Encryption, just set variable as 1.

6)

ATD<cr>

<cr><lf>OK<cr><lf>

<cr><lf>CONNECT

<cr><lf> or

<cr><lf>ERROR<cr

><lf>

Connect

to

the device

that

last

successfully connected.

7)

AT+BTSCAN<cr>

<cr><lf>OK<cr><lf>

Enable inquiry and page scans with

timeout of infinity.

8)

AT+BTSCAN,n,to<cr>

<cr><lf>OK<cr><lf>

Enable inquiry or Page scans.

If n=1, disable page and enable

inquiry.

If n=2, enable page and disable

inquiry.

If n=3, enable both page and inquiry.

Scan will be performed during <to>

seconds.

9)

AT+BTSCAN112233445566,to<cr>

<cr><lf>OK<cr><lf>

Will scan of only specified device.

10)

AT+BTCANCEL<cr>

<cr><lf>OK<cr><lf>

cancel the current pending operation

when the device is inquiring, paging

or scanning mode.

11)

+++

<cr><lf>OK<cr><lf>

Drop from online mode to command

mode.

12)

ATO<cr>

<cr><lf>OK<cr><lf>

Return to online mode if currently

being connected.

13)

ATH<cr>

<cr><lf>OK<cr><lf>

Drop the connection.

14)

AT+BTSEC,Authentication,Encryption

<cr>

<cr><lf>OK<cr><lf>

Same as AT+BTAUTH

Advertising