background image

ProBee-ZE20S-HAxx User Guide Rev 1.9

39

31

GPIO_10

Digital Output with LED(CR13) Display (Active High)

Digital Input with Button Switch (SW11, Active Low or Active High)

Analog Input with Variable Register (VR2)

32

GPIO_9

Digital Output with LED(CR12) Display (Active High)

Digital Input with Button Switch (SW10, Active Low or Active High)

Analog Input with Variable Register (VR1)

5.3.5

LEDs (CR12-19)

The development board has 8 LEDs for digital output. To enable the LEDs, the GPIO_OUT (SW20) switch

should be set to LED_ON. The LEDs are turned on when the related GPIO pins of the ZE20S are high.

Note: The ADC_0~3 switches (SW4~7) should be placed to EXT_0~3.

5.3.6

Button Switches (SW10-17)

The development board has 8 button switches for digital input. The switches can be configured as active

high or active low with the GPIO_IN (SW19) switch.

Note: The ADC_0~3 switches (SW4~7) should be placed to EXT_0~3.

Note: The LED On/Off switch (SW20) should be placed to LED_OFF.

Note: If the GPIO_IN (SW19) is set to Active High, GPIO pull up/down option should be set to Pull-Down

(ATS41=0). If the GPIO_IN (SW19) is set to Active Low, GPIO pull up/down option should be set to Pull-

Up. (ATS41=1)

5.3.7

Variable Resistors (VR1, VR2)

There are two variable resistors for analog inputs on the development board. The analog inputs can be

read with the GPIO_9 and GPIO_10. To enable the variable resistors, the ADC_0 and ADC_1 switches

should be placed to VR_0 and VR_1.

Note: The LED On/Off switch (SW20) should be placed to LED_OFF.

5.3.8

Temperature Sensor

The GPIO_11 of the ZE20S is routed to the temperature sensor. The relationship between temperature

and analog input is as follows:

Temperature(℃) ={ Volt(mV) -600(mV)} * 0.1(℃/mV)

Note: The LED On/Off switch (SW20) should be placed to LED_OFF.

5.3.9

Light Sensor

The GPIO_12 of the ZE20S is routed to the light sensor. Approximately, the relationship between

Advertising