SENA ProBee-ZE20S-HAOL User Manual

Page 65

Advertising
background image

ProBee-ZE20S-HAxx User Guide Rev 1.9

65

Default

0

Range

0 – 2

7.9.4

AT+STOPBIT or AT+US

Description

Get/Set the serial stop bit setting on the module.

Execute

AT+STOPBIT?<CR>

AT+STOPBIT=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

1

Range

1 – 2

7.9.5

AT+FLOWCTRL or AT+UF

Description

Get/Set flow control status. (0: none, 1: software, 2: hardware flow control)

Execute

AT+FLOWCTRL?<CR>

AT+FLOWCTRL=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0

Range

0 – 2

7.10 GPIO

7.10.1 AT+GPIO or AT+IO

Description

Get/Set the configuration status of GPIO individually or all at once. Only GPIO9-

14 can be set 0-5, others are available 0-3 and 5.

Execute

AT+GPIO?<CR> or

AT+GPIO<number>?<CR>

AT+GPIO=<values><CR> or

AT+GPIO<number>=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

55555000000000055

Range

GPIO9-14: 0-6, the others: 0-3 and 5-6

0

Disabled (unmonitored digital input)

1

Digital input, monitored

2

Digital output, default low

3

Digital output, default high

4

Analog input, single ended (only valid for GPIO9~14)

5

Reserved for pin-specific alternate functionalities

6

Home Automation GPIO (only valid for ProBeeHADL and ProBeeHAOL)

7.10.2 AT+DIO

Description

Get/Set the digital IO value individually or all at once. All GPIO pins can be used

Advertising