SENA ProBee-ZE20S-HAOL User Manual

Page 40

Advertising
background image

ProBee-ZE20S-HAxx User Guide Rev 1.9

40

illumination and analog input is as follows:

Illumination(Lux) = Volt(mV) * 0.25(Lux/mV)

Note: The LED On/Off switch (SW20) should be placed to LED_OFF.

5.3.10 Terminal Block

The development board has a terminal block for external analog inputs. Figure 5-2 shows the layout of

the terminal block. To use external analog inputs instead of the variable resistors, temperature sensor or

light sensor, the ADC_0 (SW4), ADC_1 (SW5), ADC_2 (SW6) or ADC_3 (SW7) should be placed on

EXT_0, EXT_1, EXT_2, or EXT_3.

Reserved

ADC_3

ADC_0

ADC_2

ADC_1

GND

AI0

GND

AI1

GND

AI3

GND

AI2

Figure 5-2 Terminal Block for External Anlalog Inputs

Note: The LED On/Off switch (SW20) should be placed to LED_OFF.

5.4

Configuration Example: 1 Coordinator and 2 End-Devices

Here is another example assuming different system configurations. This example can be described as

follows:

One ZE20S module acts as a ProBeeHACI coordinator and it is connected to a host computer via

USB cable.

One ZE20S module acts as a ProBeeHADL end device and it receives control commands from

the coordinator.

One ZE20S module acts as a ProBeeHAOL end device and it receives control commands from

the coordinator.