0000|0000|01 (Basic)

0000|0001|00 (Basic)

0000|0002|00 (Basic)

0000|0003|00 (Basic)

...

0002|0010|00 (Device Temperature Configuration)

0002|0011|0000 (Device Temperature Configuration)

0002|0012|0000 (Device Temperature Configuration)

0002|0013|000000 (Device Temperature Configuration)

0002|0014|000000 (Device Temperature Configuration)

0003|0000|0000 (Identify)

OK

# Response

# clus: cluster id

# attr: attribute id

# data: stored data

9.4

Reading Attribute

User can read attribute of local node or remote node by running the AT command as below:

AT+SREAD can be used for reading attribute of local node.

AT+CREAD can be used for reading attribute of remote node.

User should set destination address by command AT+DEST before running AT+CREAD.

Destination node must implement corresponding attribute and cluster.

Example) Read attribute of local node.

AT+SREAD=0000,0007<CR>

# Read device attribute

# Basic cluster(0x0000),

# Power source attribute(0x0007)

2

# Unlocked

OK

# Response

Example) Read attribute of remote node.

AT+DEST=0000,01<CR>

# Set destination node address

OK

# Response

AT+CREAD=0101,0000<CR>

# Read destination’s attribute

# Door Lock cluster(0x0101),

# Lock state attribute(0x0000)

Advertising