Table e4: pin out for legacy breakers, Rms7, Rms9c – GE Industrial Solutions EntelliGuard TU Trip Units User Manual
Page 103: Rms9d, Signal description, Trippwr, Main flux shifter, Pl_pwr, Remote close, Fanout
DEH-4567B
EntelliGuard TU Trip Units: UL/ANSI Models
Appendix E: GTU Pin Out Diagrams
©2012 General Electric All Rights Reserved
93
Table E-4: Pin Out for Legacy Breakers
Pin # RMS7
RMS9C
RMS9D
Signal Description
1
TRIPPWR +
N/C
TRIPPWR +
Main Flux Shifter +
2
N/C
PL_PWR
Remote Close
3
FANOUT
PHAHII
PBII HiBreak Air Core
4
N/C
PHBHII
PBII HiBreak Air Core
5
GFZIN+
PHCHII
PBII HiBreak Air Core
6
Keying Pin
GFZIN-
Keying Pin
Placement Aid for Connector
7
DGND
GFZOUT+
DGND
8
DGND
GFZOUT-
DGND
Contact Position Switch
9
/ST
Commnet -
/ST
Trip Signal from PBII Shunt Trip
10
DGND
Phase A High Inst. CT
DGND
Shunt Trip Reference
11
UVR_24 V
Phase B High Inst. CT
UVR_24 V
24 Volt Signal From PBII UVR
12
IPC +
Phase C High Inst. CT
IPC
Factory Test Communications
13
Commnet +
FANON
Fan Signal for 5000A AKR
14
24V EXTRN
Phase A High Inst. CT Rtn
24V EXTRN
24V Control Power +
15
DGND
Phase B High Inst. CT Rtn
DGND
24V Control Power -
16
Phase C High Inst. CT Rtn
VC
Phase C Voltage Input
17
Phase N CT White
VA
Phase A Voltage Input
18
FLUXSHT -
Phase A CT Return
FLUXSHT -
Main Flux Shifter -
19
Phase B CT Return
PL_RTN
Remote Close
20
Phase C CT Return
PHAHIR
PBII HiBreak Air Core
21
Phase N CT Return
PHBHIR
PBII HiBreak Air Core
22
Phase A CT Black
PHCHIR
PBII HiBreak Air Core
23
Phase B CT Black
24
BKRPOS
Phase C CT Black
BKRPOS
Contact position Switch
25
BA_MLR_P
Phase C Voltage Conditioner
BA_MRL_P
Bell Alarm Fire +
26
BA_MLR_P
IPC
BA_MRL_P
Lock Out Fire +
27
DGND
DGND
UVR 24V Ground
28
AGND
Flux Shifter -
AGND
Analog Ground
29
Phase B Voltage Conditioner
HMNET-C
Commnet +
30
GFZOUT+
Zone Select Out +
31
Aux Microswitch
GFZIN+
Zone Select In +
32
DGND
Flux Shifter +
DGND
Draw Out Switch Return
33
Phase A Voltage Conditioner
VB
Phase B Voltage Input
34
PHA+
Aux Microswitch
PHA
Phase A CT
35
PHA-
-24v Control
CTCOM
Phase A CT Return
36
PHB+
+24v Control
PHB
Phase B CT
37
PHB-
NA
CTCOM
Phase B CT Return
38
PHC+
NA
PHC
Phase C CT
39
PHC-
NA
CTCOM
Phase C CT Return
40
NA
N/C
41
FS2_RTN
NA
MRL_RTN
Lock Out Fire -
42
FS2_RTN
NA
BA_RTN
Bell Alarm Fire -
43
ST_24 V
NA
ST_24 V
24V from Shunt Trip
44
/UVR
NA
/UVR
Trip Signal from UVR
45
DGND
NA
DGND
Commnet -
46
NA
GFZOUT -
Zone Select Out -
47
NA
GFZIN -
Zone Select In -
48
NA
D_OUT
Draw Out Switch Input
49
PHN+
NA
CTN
Neutral CT
50
PHN-
NA
CTCOM
Neutral CT Return