DEH-4567B

EntelliGuard TU Trip Units: UL/ANSI Models

Appendix C: Modbus Register Map

©2012 General Electric All Rights Reserved

75

Register

Address

Modicon

Address Variable Name

Allowable Values

Notes

227

40228

GF CT Trip Pickup 1- 0.10

2- 0.11
3- 0.12
4- 0.13
5- 0.14
6- 0.15
7- 0.16
8- 0.17
9- 0.18
10- 0.19
11 - 0.20

12- 0.21
13- 0.22
14- 0.23
15- 0.24
16- 0.25
17 - 026
....
78- 0.87
79- 0.88
80- 0.89
81- 0.90

82- 0.91
83- 0.92
84- 0.93
85- 0.94
86- 0.95
87- 0.96
88- 0.97
89- 0.98
90- 0.99
91- 1.00

LCD / MODBUS

ANY IEC
GTU 17 / 40 - 0.1 - 1.0 (IEC)
NON IEC
GTU D/C - 0.2 to 0.6 (sensor <=2000A)
GTU D/C - 0.2 – 0.37 (sensor 2500 &
3200A)
GTU D/C - 0.2 – 0.3 (sensor 4000A)
GTU D/C - 0.2 – 0.24 (sensor 5000A)
GTU D/C - 0.2 (6000 – 6400)

228

40229

GF CT Trip Delay 0 - Off

1 - Band1
2- Band2
3- Band3
4- Band4

5- Band5
6- Band6
7- Band7
8- Band8
9- Band9

10- Band10
11- Band11
12- Band12
13- Band13
14- Band14

229

40230

GF CT Trip K Value 0 - 0

1 - I

2

T 2

2 - I

2

T 4.4

3 - I

4

T 19.8

230

40231

GF CT Alarm
Pickup

1- 0.10
2- 0.11
3- 0.12
4- 0.13
5- 0.14
6- 0.15
7- 0.16
8- 0.17
9- 0.18
10- 0.19
11 - 0.20

12- 0.21
13- 0.22
14- 0.23
15- 0.24
16- 0.25
17- 0.26
...
78- 0.87
79- 0.88
80- 0.89
81 - 0.90

82- 0.91
83- 0.92
84- 0.93
85- 0.94
86- 0.95
87- 0.96
88- 0.97
89- 0.98
90- 0.99
91- 1.00

231

40232

GF CT Alarm
Delay

0 - Off
1 - Band1
2- Band2
3- Band3
4- Band4

5- Band5
6- Band6
7- Band7
8- Band8
9- Band9

10- Band10
11- Band11
12- Band12
13- Band13
14- Band14

Band 1 for GACB only

232

40233

GF CT Alarm K
Value

0 - 0
1 - I

2

T 2

2 - I

2

T 4.4

3 - I

4

T 19.8

233

40234

GF Sum Trip
Pickup

1- 0.10
2- 0.11
3- 0.12
4- 0.13
5- 0.14
6- 0.15
7- 0.16
8- 0.17
9- 0.18
10- 0.19
11 - 0.20

12- 0.21
13- 0.22
14- 0.23
15- 0.24
16- 0.25
17 - 0.26
....
78- 0.87
79- 0.88
80- 0.89
81 - 0.90

82- 0.91
83- 0.92
84- 0.93
85- 0.94
86- 0.95
87- 0.96
88- 0.97
89- 0.98
90- 0.99
91- 1.00

LCD / MODBUS

ANY IEC
GTU 17 / 40 - 0.1 - 1.0 (IEC)
NON IEC
GTU D/C - 0.2 to 0.6 (sensor <=2000A)
GTU D/C - 0.2 – 0.37 (sensor 2500 &
3200A)
GTU D/C - 0.2 – 0.3 (sensor 4000A)
GTU D/C - 0.2 – 0.24 (sensor 5000A)
GTU D/C - 0.2 (6000 – 6400)

234

40235

GF SumTrip Delay 0 - Off

1- Band1
2- Band2
3- Band3
4- Band4

5- Band5
6- Band6
7- Band7
8- Band8
9- Band9

10- Band10
11- Band11
12- Band12
13- Band13
14- Band14

Band 1 for GACB only

235

40236

GF Sum K Value 0 - 0

1 - I

2

T 2

2 - I

2

T 4.4

3 - I

4

T 19.8