Table – 2 (460V)

Device

AF - 600 Hp

Rating(s)

Minimum Wire

Size

Maximum Wire

Size

Required Torque

NON FUSED

DISCONNECTOR AND FUSE

BLOCK

1 through 10

# 14 AWG

# 4 AWG

Note 1

15 through 30

# 14 AWG

# 4 AWG

Note 1

40 through 50

# 8 AWG

1/0

Note 1

60 through 75

# 8 AWG

1/0

Note 1

100 through 125

# 4 AWG

300 MCM

Note 1

150 through 300

# 2 AWG

600 MCM

Note 1

FUSED DISCONNECTOR

1 through 30

# 10 AWG

# 3 AWG

Note 1

40 through 50

# 14 AWG

# 2/0 AWG

Note 1

60 through 100

# 6 AWG

# 3/0 AWG

Note 1

125 through 250

# 2 AWG

# 600MCM

Note 1

300 through 500

2 X # 2 AWG

2 X 600MCM

Note 1

550

4 X # 2 AWG

4 X 600MCM

Note 1

Circuit Breaker

2 through 75

# 12 AWG

# 3/0 AWG

Note 1

100 through 150

# 8 AWG

350 MCM

Note 1

200 through 350

2 X 2/0

2 X 500 MCM

Note 1

200 through 350

#8 AWG

600 MCM

Note 1

450 through 500

3X #3/0 AWG

3X 500 MCM

Note 1

550 through 550

4X #250 AWG

4X 500 MCM

Note 1

Overload Relay

2 through 25

# 14 AWG

# 8 AWG

20 lb. in.

30 through 75

# 10 AWG

# 3 AWG

50 lb. in.

100 through 125

# 6 AWG

250 MCM

275 lb. in., Note 2

150 through 250

# 6 AWG

350 MCM

200 lb. in., Note 2

300

# 8 AWG

500 MCM

375 lb. in., Note 2

Drive output power

Terminal Board

1 through 10

# 24 AWG

# 10 AWG

5.3 lb.in.

15 through 20

# 6 AWG

# 6 AWG

16 lb.in.

25 through 40

# 2 AWG

# 2 AWG

40 lb.in.

50 through 60

# 1 AWG

# 1 AWG

89 lb.in.

75

4/0

4/0

212 lb.in.

100

300MCM

300MCM

212 lb.in.

125-150

2x2/0

2x2/0

Note1, 2

200 through 300

2x350MCM

2x350MCM

Note1, 2

350 through 550

4x500MCM

4x500MCM

Note1, 2