9.2.4 Soft Charge Card

1.

Remove power card mounting plate in accordance with instructions.

2.

From soft charge card, disconnect connectors MK1, MK2, Mk3, and MK4.

3.

Remove soft charge card from mounting plate by removing four screws (T25) fastening card to mounting plate. Note insulation sheet below soft charge
card. Remove and keep the insulation sheet for reinstallation.

Reinstall in reverse order of this procedure. Tighten mounting screws to 2.3 Nm (20 in-lbs).

1

2

2

1

Soft charge card

2

Attaching screw (step 3)