Figure 8 output wiring for converter shelves, Table 3 output connector pinout – GE Industrial Solutions CPS3200U User Manual

Page 19

Advertising
background image

CPS3200U Upstream System – 23” Product Manual

CPS3200U

CC848779826 r09 December 2013

19

Table 3 Output Connector Pinout

Connector for Circuits 1-8 (Shelf J1)

Connector for Circuits 9-16 (Shelf J2)

Conv Out Pos Color

Conv Out Pos Color

Conv Out Pos Color

Conv Out Pos Color

1a-

1 BL / W

1a+

26 W / BL

9a-

1 BL / W

9a+

26 W / BL

1b-

2 O / W

1b+

27 W / O

9b-

2 O / W

9b+

27 W / O

2a-

3 G / W

2a+

28 W / G

10a-

3 G / W

10a+

28 W / G

2b-

4 BR / W

2b+

29 W / BR

10b-

4 BR / W

10b+

29 W / BR

3a-

5 SL / W

3a+

30 W / SL

11a-

5 SL / W

11a+

30 W / SL

3b-

6 BL / R

3b+

31 R / BL

11b-

6 BL / R

11b+

31 R / BL

4a-

7 O / R

4a+

32 R / O

12a-

7 O / R

12a+

32 R / O

4b-

8 G / R

4b+

33 R / G

12b-

8 G / R

12b+

33 R / G

5a-

9 BR / R

5a+

34 R / BR

13a-

9 BR / R

13a+

34 R / BR

5b-

10 SL / R

5b+

35 R / SL

13b-

10 SL / R

13b+

35 R / SL

6a-

11 BL / BK

6a+

36 BK / BL

14a-

11 BL / BK

14a+

36 BK / BL

6b-

12 O / BK

6b+

37 BK / O

14b-

12 O / BK

14b+

37 BK / O

7a-

13 G / BK

7a+

38 BK / G

15a-

13 G / BK

15a+

38 BK / G

7b-

14 BR / BK

7b+

39 BK / BR

15b-

14 BR / BK

15b+

39 BK / BR

8a-

15 SL / BK

8a+

40 BK / SL

16a-

15 SL / BK

16a+

40 BK / SL

8b-

16 BL / Y

8b+

41 Y / BL

16b-

16 BL / Y

16b+

41 Y / BL

spare

17 O / Y

spare

42 Y / O

spare

17 O / Y

spare

42 Y / O

spare

18 G / Y

spare

43 Y / G

spare

18 G / Y

spare

43 Y / G

spare

19 BR / Y

spare

44 Y / BR

spare

19 BR / Y

spare

44 Y / BR

spare

20 SL / Y

spare

45 Y / SL

spare

20 SL / Y

spare

45 Y / SL

spare

21 BL / V

spare

46 V / BL

spare

21 BL / V

spare

46 V / BL

spare

22 O / V

spare

47 V / O

spare

22 O / V

spare

47 V / O

spare

23 G / V

spare

48 V / G

spare

23 G / V

spare

48 V / G

spare

24 BR / V

spare

49 V / BR

spare

24 BR / V

spare

49 V / BR

*FR GRD

25 SL / V

*FR GRD

50 V / SL

*FR GRD

25 SL / V

*FR GRD

50 V / SL

*EMI performance is enhanced when the output cable shield is grounded only at the CPS3200 end of the shield.
Attach output cabling as shown

Step

Action

2.

Mark or tag the 25 pair cables on the unterminated end with J1 and J2 to

differentiate the two cables at the splice chamber.

3.

Run the cable down the frame and attach as shown.

Figure 8 Output Wiring for Converter Shelves

4.

Use Screw and Cable tie to secure.

Advertising