3 ordering, Ordering codes, Lugs – GE Industrial Solutions CPS3200U User Manual

Page 9: Table 2 ordering codes

Advertising
background image

CPS3200U Upstream System – 23” Product Manual

CPS3200U

CC848779826 r09 December 2013

9

3 Ordering

Ordering Codes

This is a short list of CPS3200 items that can be purchased. See Line Power Product Line Brochure for detail.

Table 2 Ordering Codes

CODE

COMCODE

DESCRIPTION

Items for new installation or growth of existing installations

QS912A

108996732

Converter Shelf with Alarm Module (provides landings for double-hole lugs)

QS982A

108996641

Converter Card (For first install on single shelf systems the sum of converters cards

and converter slot fillers should be 16. For example: 14 Converter cards and 2

Converter slot fillers)

CC109121992 Converter slot filler

QS930A

108996930

Fan Shelf with 2 redundant fan trays

QS941A

108996947

Controller with Display and Ethernet capabilities

CC848756577 Airflow baffle without bracket for air filter

CC109102638 Airflow baffle with bracket for air filter. Includes air filter.

Replacement air filter CC109121984 listed below.

Spares: Items for repair or maintenance of existing installation

CC109121984 Air filter to be used with Airflow baffle CC109102638 (Spare)

QS930B

108997623

Fan tray assembly (Spare)

QS920A

CC109102118 Alarm Module (Spare)

Expansion Items: Provide a 4 ft long wireset to transmit alarm signals past a baffle.

Use when adding a second fan shelf to an existing system.

H5694820G050 CC109122074 Fan Shelf w/2 fan trays, wireset, baffle, filter, controller cover

H5694820G051 CC109132271 Fan Shelf w/2 fan trays, wireset, baffle, controller cover

H5694820G012 CC109122082 Converter Shelf, RJ45 wireset, hardware, alarm board (same as QS912A above)
Note: A baffle must be placed above the topmost converter shelf for use in customer premise locations for UL safety

compliance. Baffles are not required in restricted access locations such as outside plant cabinet, CEV or hut locations.
The baffle can be ordered separately from the above list or in combination with a fan shelf by choosing an item from

this list.

Lugs

GA

Description

WP-91412

List

Comcode

Burndy Equivalent

Similar Lugs

NOTE: May have different dimensions.

Panduit

T&B

2

Straight, STR

54

405348202

YA2CL-2TC14

LCD2-14A-Q

54207 (STR)

2

Straight, FLEX

8

405347683

YAV2C-L2TC14-FX

LCDX2-14A-E

54208 (Flex)

2

45°, STR

-

-

YA2CL-2TC14-45

LCD2-14AH-Q

54207UF (STR)

2

45°, FLEX

193

408210524

YAV2C-L2TC14-FX-45

LCDX2-14AH-E

54208UF (Flex)

4

Straight, STR / FLEX

5

405347576

YAV4C-L2TC14-FX

LCDX4-14A-L (FLEX)
LCD4-14A-L (STR)

54206 (STR)
54206 (FLEX)

4

45°, STR / FLEX

-

-

YAV4C-L2TC14-FX-45

LCDX4-14AH-L (FLEX)
LCD4-14AH-L (STR)

54206UF (STR)
54206UF (FLEX)

6

Straight, STR / FLEX

3

405347519

YAV6C-L2TC14-FX

LCDX6-14A-L (FLEX)
LCD6-14A-L (STR)

54205 (STR)
54205 (FLEX)

6

45°, STR / FLEX

-

-

YAV6C-L2TC14-FX-45

LCDX6-14AH-L (FLEX)
LCD6-14AH-L (STR)

54205UF (STR)
54205UF (FLEX)

8

Straight, STR / FLEX

75

406021626

YA8CL2TC14

LCDX8-14A-L (FLEX)
LCD8-14A-L (STR)

542040410 (STR)
542040410 (FLEX)

8

45°, STR / FLEX

-

-

YA8CL2TC14-45

LCDX8-14AH-L (FLEX)
LCD8-14AH-L (STR)

N/A

Advertising