9 reference information, Qs982a converter led information map, Figure 36 qs982 leds and test points – GE Industrial Solutions CPS3200U User Manual

Page 37: Table 5 qs982a converter led information map, Overview

Advertising
background image

CPS3200U Upstream System – 23” Product Manual

CPS3200U

CC848779826 r09 December 2013

37

9 Reference Information

Overview

This section contains additional information (connector pin designations, etc.) that may be required for making,

customizing, or troubleshooting system connections.

QS982A Converter LED Information Map

Figure 36 QS982 LEDs and Test Points

Table 5 QS982A Converter LED Information Map

Action Required

OK LED

Fault LED

Conditions

Notes

None

Green

Off

All OK

Verify circuit

configuration

Off

Yellow

Standby

Standby can be set using the QS941

controller display or remotely using a

web browser.

Check seating on

Alarm card and

converter card

Green

Blink Red On ½ second,

Off ¼ second

Loss of comm.

Check 5 pin

protectors and faults

to ground

Red Blink

Red Blink

Ground fault

Check output lines for

shorts to each other

Green

Yellow Blink

Overcurrent or under

voltage

Replace unit

Red Blink

Off

OV or internal failure

Solve Thermal

problem

Off

Red Blink

Thermal Alarm

Latch off after 3 retry cycles

Check source voltage Off

Off

card not powered or

input fuse failure

Observe Lamp Test

Bi-Color: 4.5 seconds

on, 4.5 seconds on and

1 second off

Bi-Color: 4.5 seconds

on, 4.5 seconds on and

1 second off

Lamps test requested

from controller

Advertising