Extron Electronics MTPX Plus Series User Guide User Manual

Page 100

Advertising
background image

X6#

= Verbose mode

0 = clear/none (default for Telnet connection)
1 = verbose mode (default for RS-232/RS-422 connection)
2 = tagged responses for queries
3 = verbose mode and tagged for queries

NOTE: If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command

does (for example, the read matrix name command

E

CN

}

, returns Ipn•

X4)]

).

X6$

= Flow control

hardware, software, none (only the first letter required)

X6%

= Data pacing (in ms between bytes)

0000 (default) - 1000

X6^

= Time (in 10 ms increments) to wait for characters

10 (= 100 ms, default) - 32767

X6&

= Time (in 10 ms increments) to wait between characters

2 (= 20 ms, default) - 32767

X6*

= Port timeout interval (in 10-sec. increments)

1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)

Command/Response Table for IP-specific SIS Commands

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

IP setup commands

Set matrix name

EX4)

CN

}

Ipn•

X4)]

Read matrix name (location)

E

CN

}

X4)]

Reset matrix name to factory default

E

•CN

}

Ipn•

X4)]

Set time and date

E

X4@

CT

}

Ipt

X4@]

Read time and date

E

CT

}

X4#]

Set GMT offset

EX4$

CZ

}

Ipz

X4$]

In the command, the divider between
hours and minutes can be either a
colon or a period. In the response, the
divider is a colon.

Example:

E

8.3CZ

}

Ipz+08:30

]

8.3 = 8:30

Read GMT offset

E

CZ

}

X4$]

Set Daylight Savings Time

EX4%

CX

}

X4%]

Read Daylight Savings Time

E

CX

}

X4%]

Set IP address

EX4^

CI

}

Ipi

X4^]

Read IP address

E

CI

}

X4^]

Read hardware address

E

CH

}

X4&]

Reads MAC address.

Read # of open connections

E

CC

}

X4*]

Set subnet mask

EX4^

CS

}

Ips

X4^]

Read subnet mask

E

CS

}

X4^]

Set gateway IP address

EX4^

CG

}

Ipg

X4^]

Read gateway IP address

E

CG

}

X4^]

Set administrator password

EX4(

CA

}

Ipa•

X4(]

Read administrator password

E

CA

}

X4(]

Reset (clear) administrator password

E

•CA

}

Ipa•

]

Set user password

EX4(

CU

}

Ipu•

X4(]

Read user password

E

CU

}

X4(]

Reset (clear) user password

E

•CU

}

Ipu•

]

Set mail server, domainname

EX4^

,

X5)

,

X4(

CM

}

Ipm

X4^

,

X5)

,

X4(]

Read mail server, domainname

E

CM

}

X4^

,

X5)

,

X4(]

Set e-mail recipient

EX5!

,

X5@

CR

}

Ipr

X5!

,

X5@

,

]

This command sets the recipient. To
receive e-mail notifications, you must then
set the events that the switcher reports,
using one or more separate Set e-mail
events (EM) commands (see next page).

Example:

E

72,[email protected]

}

Ipr72,[email protected]

,

]

Read e-mail recipient

EX5!

CR

}

X5@

,

]

MTPX Plus Series • Programming Guide